NameYMCA CHILDRESS KLEIN
Address301 S COLLEGE ST
ONE WELLS FARGO STE 200
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/31/2019
Final Score @ Grade
22
General CommentsIntent to suspend issued for self-latching door, drain cover, and chemical storage. Inspection completed by Sarah Coppa.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521 Install ladders per manufacturer instructions. Ladder closest to the lifeguard chair is loose. Repair needed.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No .2537(8) Fittings and/or face plates shall be replaced when damaged and kept in good repair. Drain cover not secure on gutter of right side on pool. Repair needed. Intent to suspend.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2537(b) All gates and doors shall be self-closing, self-latching. Door to stair well is not self-latching. Repair door to self-latch. Intent to suspend issued.
22 6 Premises: emergency telephone provided No No No .2530(f) Emergency phone shall remain operable. Emergency phone not functioning. Temporary phone placed on cardio floor within 75 feet of bather entrance. Contact Katie Wilson once phone repaired to verify phone is corrected.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2534(5) Chemicals shall be stored as to prevent a reaction and permit for easy clean-up. Liquid chemicals stored above dry chemicals in pump room. Intent to suspend.
27 2 Equipment room: filter backwash discharged through an air gap No No No .2513(b) Filter backwash shall be discharged through an air gap. No air gap at backwash line to pit.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2626(i) Water in restrooms shall not exceed 110 F. Water temperature at restroom handsink >110 F.