NameYMCA CHILDRESS KLEIN
Address301 S COLLEGE ST
ONE WELLS FARGO STE 200
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/27/2017
Final Score @ Grade
26
General Comments2 - Chlorine noted as below 1.0 ppm at openings on some days. Assure chlorine is maintained at least 1.0 ppm while pool is open to the public. 23 - Chlorinator not verified during inspection. Liquid chlorinator. Assure chlorinator can detect flow and turns off when no flow of water. Head CPO not at site today.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Alkalinity not recorded weekly. Record weekly and maintain log books accessible. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algea build-up begining on pool floors and walls. Keep clean.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Some rust on ladder handrails. Keep in good repair.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Some drain covers loose at coping around the pool (specifically at 3 1/2 ft to left of door entrance). Assure all fixtures secure and in good repair.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Front doors into pool not self-closing, self-latching. All doors on to pool deck shall be self-closing, self-latching. Intent to Suspend issued.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational. Keep operational.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap above pit.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water >112 F in restrooms and shower head holder damaged in one shower stall. Maintain water at 110 F or below and repair holder.