Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameYMCA DOWD SHALLOW
Address400 E MOREHEAD ST
 
City/State/ZIP
CHARLOTTE NC 28202
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/30/2016
Final Score @ Grade
16
General Comments5 - General Comment - Records not maintained daily in log book located in pump room. Record chlorine, pH, main drain checks and temp daily. Note: Chlorinator could not be verified. CPO not onsite.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Water level low in pool and barely hitting skimmer line. Increase water level so that skimmers operate properly.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 4 ft deck depth marker at far end of pool with white build-up. Continue to clean to keep all depth markers clearly visible.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Hose across deck used for handicap lift. Hose is greater than 1/2" thick and provides a trip hazard. Eliminate trip hazard by decreasing hose size, eliminating when not in use, or covering with safety mat. Intent to Suspend hazard.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room unlocked. Keep locked when not in use. Piping on pump room floor that requires stepover to access equipment. Maintain 3 ft clear walking space around all equipment.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Water in restrooms >120 F. Maintain at 110 F or below.