NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 1/31/2024
Final Score @ Grade
28
General CommentsIntent to Suspend issued for: .2524/.2537 - repair light for night swimming approval on exterior light. Todd Woodard present during the inspection. Also, spoke with management pertaining to repair of the gate.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No temperature logs for several days in January and December. Ensure daily record keeping for temperature.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Both ladders loose. Keep tightened and secure.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4" between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Gates with horizontals at >30" meeting code exception requirement at 30" to 45" between horizontals since pre-2010. Exterior barrier with decorative features that provide footholds. Per pool operator gates are ADA access gates. Pool gates prior to 2010. Per operator, battery back-up installed at gates. One gate leads to handicap ramp for ADA accessibility. One gate leads to step and leads into pool. Gate shall swing away from the swimming pool and self-close, self-latch. Provide documentation that gate with steps is required for egress to swing into the pool. If not, gate shall be repaired prior to May 1, 2024 operating permit. Discussed with operator and manager the following: 1) Changing gate swing and hinges so that gate swings away from the pool. 2) Eliminating gate by permanently disabling of ok'd by fire department. 3) Changing latching mechanism to magna-latch and change gate swing away from the swimming pool. Ensure magna-latch at 54" from ground. Outdoor portion of pool contains separate gate that also does not meet code requirements. Gate leads to additional space which is fenced in with barrier that does not meet code requirements. See reference above. Gate is locked shot.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One light not operable closest to emergency phone. Pool approved for night swimming. Repair light. Photograph documentation ok once repaired. Intent to Suspend issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Multiple leaks at chlorinator on inlet and outlet line. Repair leak. No flow meter on chlorinator. Original construction. If repaired/replaced, install per NSF requirements.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Small leak around top of outdoor filter. Repair leak.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Piping run across floor in pump room for equipment. Ensure 3 ft. clearance around equipment. Original construction. .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. Floor wet in pump room due to leak at chlorinator and outdoor filter. Keep dry.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Could not verify mirrors as shatterproof in restrooms. Ensure shatterproof mirrors provided.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib and floor drain in restrooms. Original construction. Provide hose bib and floor drain.