Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/24/2023
Final Score @ Grade
18
General CommentsTodd Woodard present during the inspection. Intent to Suspend issued for .2518 - flow meter not operable. Maintain at 20 gpm flow for flow restriction. Given 30 days to provide documentation on gate or must be repaired. Replace indoor ring buoy with new USCG approved ring buoy. If rope replaced, required at 30 ft. Throw rope replacement not required at time of inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4" between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Per pool operator gates are ADA access gates. Pool gates prior to 2010. Per operator, battery back-up installed at gates. One gate leads to handicap ramp for ADA accessibility. One gate leads to step and leads into pool. Gate shall swing away from the swimming pool and self-close, self-latch. Provide documentation that gate with steps is required for egress to swing into the pool. If not, gate shall be repaired prior to May 1, 2024 operating permit. Outdoor portion of pool contains separate gate that also does not meet code with same observations.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Some sealant on decking chipping up. Continue to monitor. May require repair in the future if worsens.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Leak at chlorinator valve. Repair leak. No flow meter on chlorinator. Original construction. If repaired/replaced, install per NSF requirements.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not operational on indoor pump. Required flow restriction at 20 gpm. Could not verify flow. Replace flow meter with operable flow meter. Intent to Suspend issued.