Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/28/2022
Final Score @ Grade
36
General CommentsTom Woodard, CPO, present during the inspection. Note equalizers expire on April 1. New equalizers are required with updated PDSC form by April 1 or permit will be suspended. Your old PDSC form can be found on our website at http://meckpools.charmeck.org. Intent to Suspend issued for expired reagents and deck damage and rusted screws on deck. Lights verified operational for night swimming approval.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Multiple test reagents expired. Replace expired reagents. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some debris on pool floor. Keep pool clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir missing from outdoor skimmer. Replace weir. Some minor damage to skimmer basket at skimmer closest to emergency phone. Continue to monitor and replace as needed.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No End caps missing from multiple ladders. Replace end caps. Ladder in deep end loose. Tighten.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4" between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Per pool operator gates are ADA access gates. Pool gates prior to 2010. Per operator, battery back-up installed at gates. Outdoor portion of pool contains separate gate that also does not meet code with same observations.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damage to deck in two locations outside and three locations inside. Repair decking where needed. Intent to Suspend issued. Rusted screws on one deck drain. Replace screw drains. Intent to Suspend issued. Some standing water on floor near entry to indoor pool. Floor shall be sloped to drain. Monitor standing water so that it does not become a slip hazard.
22 6 Premises: emergency telephone provided No No No Phone number posted did not match 911. Corrected and verified during the inspection.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Original construction. If repaired/replaced, install per NSF requirements.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet due to leak at boiler. Keep floor dry due to electrical equipment in pump room.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib and floor drain in restrooms. Original construction. Provide hose bib and floor drain.