Premises Information

Return to Inspections
NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 9/29/2021
Final Score @ Grade
34
General Comments15 - One ring buoy with grab rope starting to degrade. Requires replacement prior to 2022 operating permit. Intent to Suspend issued for pump basket and deck damage. Todd Woodard present during inspection.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No New pump installed. Numbers run while in field and approved with new pump SF-N1-1 1/2A, 1.5 hp pump. Meets restrictions of pump room. Electrical inspection passed September 2021. New pdsc form filled out while onsite. For any future pump changes, submit in-field plan review application with updated pdsc form.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algae on pool walls. Continue to monitor and treat as needed.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer weir missing on outside pool. Install weir.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder furthest from phone loose and missing end caps. Secure and replace end caps.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4" between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Per pool operator gates are ADA access gates. Pool gates prior to 2010. Per operator, battery back-up installed at gates. Outdoor portion of pool contains separate gate that also does not meet code with same observations.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damage to deck in two locations and sharp edge near skimmer. Repair deck. Intent to Suspend issued.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Original construction. If repaired/replaced, install per NSF requirements.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No New pump installed. Provide spare pump basket. Intent to Suspend issued.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib and floor drain in restrooms. Original construction. Provide hose bib and floor drain.