NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/16/2020
Final Score @ Grade
26
General CommentsEmergency phone number listed is for front desk which is answered by automated system. Ensure emergency phone number can be directly reached by front desk person. Given 30 days to correct. Will verify on return visit. Intent to Suspend issued for record keeping (temp), test kit, pool signage (Children should not use the swimming pool...), mirror in restroom, and pool decal.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No .2535 (11) The pool operator shall inspect the pool at least daily and maintain written records. Written records missing temperature recordings. Include temperature of pool in daily records. Intent to suspend issued. .2535(10) Provide test kit capable of measuring disinfectant level, cyanuric acid and total alkalinity. Test kit with CYA tube with build-up. Provide new test kit. Intent to Suspend issued.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2514(c) Pool finish shall be white or light colored. Decal on pool floor. Operator stated that decal was used to cover up damage to plaster. Eliminate decal and repair plaster. Intent to Suspend issued.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4" between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Per pool operator gates are ADA access gates. Pool gates prior to 2010. Per operater, battery back-up installed at gates. Outdoor portion of pool contains separate gate that also does not meet code with same observations.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Minor deck damage at outdoor decking. Continue to monitor to ensure it does not worsen.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Children should not use the swimming pool without adult supervision." in 1" lettering. Sign in outdoor pool area observed without exact wording. Provide additional sign to outdoor pool area with required wording. Intent to Suspend issued.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(c) Valves and controls shall be accessible to the pool operator at all times. Maintain 3 ft. clear walking space in pump room. <3 ft of clear walking space in pump room.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. New piping installed due to leak per operator are missing labeling. Label pipes.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No .2526(k) Provide shatterproof mirrors. Mirror in restrooms not shatterproof. Provide shatterproof mirror. New mirror installed with renovation. Must meet current code. Intent to Suspend issued.