Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/6/2019
Final Score @ Grade
20
General CommentsPool pump motor changed per operator. Ground wires not visibly connected to pumps. No permits pulled. Will refer to Code Enforcement. Permits shall be pulled by end of day on 8/8/19 or permit will be suspended.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Minor damage to skimmer basket. Replace as needed. Damage does not affect filtration. .2518(k) Surface skimmers shall be installed per manufacturer's instructions.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder rungs >6" from pool wall. .2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Outdoor rope length at 33 ft. Required at 30 ft. Corrected during inspection. .2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No .2528 Gate and fencing shall meet rule .2528. Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4" between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Per pool operator, gates are ADA access gates. Pool gates prior to 2010. Per operater, battery back-up installed at gates.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Minor damage to decking near skimmer by emergency phone. Continue to monitor decking. Repair as needed. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Deck drains are missing screws. In place but not attached. .2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.