Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Minor damage to skimmer basket. Replace as needed. Damage does not affect filtration.
.2518(k) Surface skimmers shall be installed per manufacturer's instructions. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
Ladder rungs >6" from pool wall.
.2521(b) Distance between wall and ladder rung shall range 3" to 6" measured from wall. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Outdoor rope length at 33 ft. Required at 30 ft. Corrected during inspection.
.2530(a) Provide ring buoy for rope 1.5 times the width of the pool or 50 ft whichever is less. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528 Gate and fencing shall meet rule .2528. Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4"
between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Per pool operator,
gates are ADA access gates. Pool gates prior to 2010. Per operater, battery back-up installed at gates. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Minor damage to decking near skimmer by emergency phone. Continue to monitor decking. Repair as needed.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile.
Deck drains are missing screws. In place but not attached.
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. |