7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537 Eliminate pinch hazards in pool. Light not flush to wall in outdoor pool area. Repair flush to wall so opening <1/2". Current pinch hazard. Light is light that was burnt out. Intent to Suspend issued. |
|
11
|
2
|
Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair |
No |
No
|
No |
.2521 Install ladders per manufacturer instructions. Outdoor ladder loose. Keep in good repair. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528 Gate and fencing shall meet rule .2528. Pool fencing does not meet rule requirements. Pool built prior to 2010. Observed >4" between horizontals. Perimeter fence on indoor at 42" in height with footholds. Perimeter gates swing into pool. Per pool operator, gates are ADA access gates. Pool gates prior to 2010. Per operater, battery back-up installed at gates. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
.2537(2) Decks shall be kept free of trip hazards or offsets greater than 1/2" due to deterioration or changes from original deck profile. Deck damage next to pool indoor. Repair. Intent to Suspend issued. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
.2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Warning No Lifeguard signage faded outside. Replace signage. Intent to Suspend issued. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
.2524(c) Illumination shall be sufficient so that the pool floor is visible at all times. One light burnt out in pool and one perimeter light burnt out. Pool hours are for Night Swimming. Night swimming is not approved until lighting is repaired. Intent to suspend issued. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational. Flow meters not operational. Repair so operational. Intent to Suspend issued.
.2518(h) Provide approved pump in good repair. At least one pump leaking. Repair leaks so flooring kept dry. Intent to Suspend issued.
.2518(e) Provide a spare basket for pump. No spare pump basket for pumps. Provide spare pump basket. Intent to Suspend issued |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels. Piping not clearly identified in pump room. New filters had been installed and piping re-plumbed. Clearly identify piping for indoor and outdoor. Currently piping does not correspond to what was submitted on the PDSC form. See general comment page. Intent to Suspend issued. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2626(i) Water in restrooms shall not exceed 110 F. Water in restrooms >120 F. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
.2512 Provide backflow prevention devices on all hose bibs. Outdoor hose bib without backflow prevention device. |