Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 6/19/2017
Final Score @ Grade
22
General CommentsUpdated VGB paperwork was not received for change of EQ line covers on pool. Pool operating without a permit upon arrival. Received updated paperwork during inspection and issued permit onsite.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Cyanuric acid >100 ppm. Records show 90 ppm. Lower acid to below 100 ppm and maintain records. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder not secure. Pulls out of ground when handles are pulled up on. Secure ladder.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One return missing eyeball on wall on outside pool. Replace eyeball.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates on to pool deck swing into pool. Gates shall swing away from pool. One gate is handicap access and other gate is located at stairs. Footholds on outside of fence wall. Greater than 4" between wall and fence on outside wall. Barrier at 38" on outside wall. >5" between vertical pickets on outside fence. <45" between horizontals on gates. Maintain 4" or less between pickets. Maintain fence at 48" or greater. Eliminate footholds on outside of fence. Foothold is considered anything 45" or less. Gates with horizontals 38" between. Pool built in 1985 and meets 30" to 45" requirement.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Post/pillar located directly next to pool. Considered decorative feature. No furniture behind pillar to ensure all of pool can be viewed.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Coupling leaking on one pump in pump room. Repair leak.