NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/25/2016
Final Score @ Grade
40
General Comments6 - General Comment: Equalizer line covers are due to expire in April 2017. New APSP standards allow for equalizer lines to be permanently plastered over to eliminate suction hazard as long as other means available to provide water to skimmer. Submit an updated PDSC form with equalizer information or without, once corrections are made. 15 - General Comment: Two ropes for ring buoys fraying. Replace with 30 ft rope per with sizing per public swimming pool rules. Given 30 days. General Comment: One ring buoy with some damage. Replace with USCG approved within 30 days. Note: Restrooms used for pool were built without hose bib or floor drain.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Acid not recorded regularly. Record cyanuric acid weekly.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Some algea at partition to inside/outside. Keep floor clean.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One damaged skimmer basket. Replace.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Ladder located 9" from pool wall. Maintain 3" to 6". Pool built prior to 2010. One ladder missing end cap. Replace end cap.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No One fitting missing from wall return. Replace fitting.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates on to pool deck swing into pool. Gates shall swing away from pool. One gate is handicap access and other gate is located at stairs. Footholds on outside of fence wall. Greater than 4" between wall and fence on outside wall. Barrier at 38" on outside wall. >5" between vertical pickets on outside fence. <45" between horizontals on gates. Maintain 4" or less between pickets. Maintain fence at 48" or greater. Eliminate footholds on outside of fence. Foothold is considered anything 45" or less.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Pool furniture 3 ft to pool edge. Maintain 5 ft clearance around pool in all locations.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No One light burnt out in pool on inside. For Night Swimming, repair lighting.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Both flow meters not operable. Replace flow meters.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor wet. Keep dry.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Piping not clearly identified. Labeling has worn off. Clearly identify all pipes with color codes or labels.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No No hose bib on pool deck. Provide so that all areas of deck can be reached with a 100 ft hose.