Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 8/31/2015
Final Score @ Grade
34
General CommentsImmediate Suspension issued for pH. Once corrected, call Katie at 704-309-5494 to schedule a return visit to open pool.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 6.8. Maintain between 7.2 and 7.8. Immediate Suspension issued.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Acid not recorded weekly. Record acid weekly.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One damaged skimmer basket. Replace basket.
15 6 Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located No No No Ring buoy tied improperly to indoor buoys so less than 30 ft. Corrected during inspection. Note: One indoor buoy rope fraying. Replace as needed.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gates on to pool deck open into pool. Must open away from pool. Fencing/walls around pool <48". Outdoor fencing with >4" between horizontals. Pool fence/barrier does not meet code in multiple locations. Maintain 48" in height with no footholds and <4" between horizontals.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No One flow meter stuck. Keep operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some water on pump room floor. Keep dry.Filtration not clearly accessible in pump room. Provide 3 ft clear walking space around all equipment.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Piping not clearly identified on filtration system. Clearly identify all pipes with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash pit drain appears to be clogged. Must be able to drain.