2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Pool chlorine at 0.2 ppm. Maintain at 1.0 ppm or greater. Immediate Suspension issued. |
|
4
|
6
|
Water quality: water temperature of heated pool |
No |
No
|
No |
Pool temperature at 92 F. Heated pool. Maintain at 90 F or below. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Records not maintained for last three days. Record chlorine, pH, temp and main drain check daily. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
One skimmer basket damaged. Replace weir. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Fence around inside perimeter <48" in height; gates open into pool. >4" between verticals and footholds on outdoor fence. Maintain fence in accordance with .2528. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Severe deck damage on deck outside. Repair deck where needed. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Phone inoperable. Corrected during inspection. Phone has the main line phone number posted. No rollover lines allowed. Verify designated line for phone. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
One of two flow meters not operable. Repair flow meter. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Floor wet in pump room. Keep dry. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
No labeling on pipes or worn off. Clearly identify all pipes with color codesor labels. |