Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSHERATON CHARLOTTE AIRPORT HOTEL
Address3315 SCOTT FUTRELL DR
 
City/State/ZIP
CHARLOTTE NC 28208
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/26/2014
Final Score @ Grade
30
General Comments

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Observed debris on pool floor. Keep clean.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Observed 8" between wall and ladder handrail. Maintain 3" to 6".
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Observed gate swings into pool; fence height inside <48"; >4" between verticals outside. Provide fencing in accordance with .2528.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed some damage to deck near skimmer. Keep in good repair.
22 6 Premises: emergency telephone provided No No No Observed emergency phone not connected. Corrected during inspection.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Observed leaking gasket on pump. Repair.Observed both flow meters not operational. Repair and replace one with chlorine.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed soda ash stored on floor. Corrected during inspection. Observed pump room floor wet. Keep dry.
27 2 Equipment room: filter backwash discharged through an air gap No No No Observed no air gap at backwash line to pit. Provide air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Observed water >115 F and soiled toilet in men's. Maintain water at 110 F or below and keep fixtures clean.