NameJEWISH COMMUNITY CENTER - INDOOR
Address5007 PROVIDENCE RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/5/2019
Final Score @ Grade
16
General CommentsITS for doors self-closing, self-latching or audible alarm, 5' clearance and flow meter. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Unable to verify chlorinator at time of inspection due to lack of staff available (swim lessons starting at time of inspection). PADDOCK DRAIN COVERS - REQUIRED SCREW REPLACEMENT EVERY 7 YEARS AND RE-CERTIFICATION OF DRAINS EVERY 10 YEARS FROM DATE OF INSTALL. Installed April 2009, provide required documentation for permit 2019.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Door from hallway into pool area, door from women's locker room onto pool deck and back door to outside from pool deck, not self-closing, self-latching at time of inspection. .2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm. **30 Day Intent to Suspend (ITS) item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Benches and belongings within 2 feet of pool at time of inspection. Swim lessons in session at time of inspection. If items are in use and in pool, items may be present, but otherwise need adqequate storage space and seating arranged to maintain 5' clear walking space. .2522(b) Provide at least 5 ft of clear walking space around the pool at all times. **30 Day ITS item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck at time of inspection. .2518(g) Keep flow meter operational. **30 Day ITS item
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Some chemicals stored in pump room. .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2534.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms over 110 degrees F at time of inspection. .2626(i) Water in restrooms shall not exceed 110 F.