Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameJEWISH COMMUNITY CENTER - INDOOR
Address5007 PROVIDENCE RD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 11/28/2017
Final Score @ Grade
32
General Comments15 - Push buttons on body hook. Could not remove but replace with screw by 30 day return visits to assure secured. Intent to Suspend issued for temperature logs, depth markers on pool walls, and doors on to deck self-latching, self-closing.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Temperature logs not maintained. Maintain daily temperature logs. Intent to Suspend issued.
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No 27 ft between depth markers on wall at shallow near pump room. 32.5 ft between wall depth markers at deep end. Assure depth markers maintained 25 ft apart or less in 4" lettering. Depth marker sticker worn off at 6 ft 3 in. Replace to maintain 4" height requirement and contrasting. Intent to Suspend issued for both items.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder handrail loose. Keep tightened.
12 4 Pool maintenance: inlets and other fittings in place and in good repair No No No Fixtures holding one main drain into place rusted. Keep fixtures in good repair. All fixtures shall be stainless steel in pool.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No One door on to deck not latching when closing. Restroom doors and double doors not self-closing, self-latching. Repair to self-close, self-latch or provide audible alarm at entry points. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Observed deck near pump room with rust and some build-up on deck. Keep clean and in good repair.
21 4 Premises: pool and deck lighting provided at pools that operate at night No No No Lights not operable in pool. For night swimming, lights shall be operational or main drains must be clearly visible at all times including all areas of pool deck.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Filter leaking and flow meter not operational. Repair filter (was being repaired during inspection) and keep flow meter operational.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Light burnt out and forced ventilation not operable in chemical storage room. Repair light and maintain continous forced ventilation in chemical storage room.