5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Daily records missing pool maintenance activity. Record activities pertaining to pool maintenance. All other records correct. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Ring buoy and body hook not accessible due to plants in front of them. Ensure emergency equipment is easily accessible. Operator moved plants. Corrected.
Inside pool ring buoy beckett is detatched. Outdoor pool not in use and covered. Ensure life saving equipment is in good repair. Moved outside buoy to inside pool area. Will verify outdoor buoy is replaced at return visit for ITS items. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Door in fitness area to hallway and into fitness room which leads into pool area does not self-close, self-latch or have audible alarm. Doors must self-close, self-latch or have audible alarm.
Latch height 53" at back left gate at time of inspection. Gaps under fencing greater than 4" outside. Maintain at least 54" latch height and no more than 2" to 4" gap heaight from ground to bottom of fence.
****30 Day Intent to Suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Chairs and plants within 5' of pool. Maintain 5' deck Clearance. Operator moved. Corrected. (Outdoor pool 6' clearance).
Trip hazards greater than 1/2" offset from holes for ladders outside. Cover holes to eliminate trip hazard.
**30 Day Intent to Suspend item. |
|
21
|
4
|
Premises: pool and deck lighting provided at pools that operate at night |
No |
No
|
No |
Light fixture in pool by outdoor divider not working at time of inspection. Ensure adequate lighting is provided and working properly.
**30 Day Intent to Suspend item. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Indoor emergency phone not dialing correctly (1 dial button stuck) at time of inspection. Ensure emergency phone works. Operator replaced and corrected. (See note under general comment, outdoor pool pone was used, need to replace outdoor phone). |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Ensure flow meter is working properly. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water over 110 degrees F in restroom. Maintain hot water at 110 degrees F and below.
Mirror cracked in women's restroom. Keep in good repair and shatterproof glass. |