3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH 7.0. .2535(1) Maintain pH at 7.2 to 7.8. - Corrected to 7.2. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No recent total alkalinity checks. Records show pH was consistently 7.0 for last 2 weeks with no corrective action taken. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for total alkalinity and cyanuric acid if used. - Intent to suspend item. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
Buildup of sand and debris in deep end of the pool. .2537(14) Keep pool surface and pool floor free of debris. - Intent to suspend item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some weirs missing. .2518(k) Provide functional weirs. - Intent to suspend item.
Skimmer lid damaged. .2518(k) Replace damaged skimmer lid. - Intent to suspend item.
Most skimmer baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction. - Intent to suspend item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Emergency exit door not self-closing. Door to adjoining gym not self-latching. .2537(b) All gates and doors shall be self-closing, self-latching. - Intent to suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Standing water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Fill spout angles down to pool edge. .2512(c) Over the rim fill spouts shall be at least two pipe diameters above the deck or pool overflow level. |