Premises Information

Return to Inspections
NameYMCA LAKE NORMAN INDOOR
Address21300 DAVIDSON ST
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 12/17/2020
Final Score @ Grade
14
General CommentsInspection conducted with Teresa Bostic. Due to COVID-19 precautions, inspection was not signed by the aquatics coordinator. Some skimmer lids coming unglued. Reglue lids back together. Paddock drain covers need a yearly inspection between April 2020 and April 2021. Have covers inspected and provide copy of inspection results to Environmental Health prior to the end of April 2021. “Executive Order No. 141 or subsequent Orders are in effect unless such Orders are rescinded or superseded by another applicable Order.”

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent total alkalinity checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly total alkalinity checks.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One weir installed backwards, another installed upside down. .2518(k) Install weirs per manufacturers instructions. Most skimmer baskets with debris. .2518(k) Keep skimmers free of debris so skimmers are capable of operating per manufacturer instruction.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No Handrails loose. .2521 Maintain handrails secure and in good condition.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. .2518(g) Keep flow meter operational. Spare pump basket not observed. .2518(e) Provide a spare basket for pump.