8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Observed one missing weir.
.2518(k) Replace missing weirs. |
|
15
|
6
|
Premises: body hook and ring buoy with throw rope or lifeguard with rescue tube provided and properly located |
No |
No
|
No |
Observed ring buoy rope knotted and beckets not secure. CDI - Ring buoy discarded as it is not required, pool is always lifeguard.
.2530(a) Lifesaving equipment includes body hook and pole and USCG approved ring buoy with required rope length. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Observed office and locker room doors not alarmed as required.
.2528(a) Ground level doors shall be self-closing, self-latching or child protected by audible alarm.
Intent to Suspend |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Observed emergency phone not operating. Office phone is immediately off pool deck. Provide sign indicating location of phone, located in office. Provide dialing instructions, phone number and address of facility at phone. Completed during inspection.
.2530(f) Emergency phone shall remain operable. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Observed flow switch for automatic chlorinator and acid feeder not operational
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation.
Intent to Suspend |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed flow meter not operational.
.2518(g) Keep flow meter operational.
Observed no spare pump basket.