Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameYMCA LAKE NORMAN INDOOR
Address21300 DAVIDSON ST
 
City/State/ZIP
CORNELIUS NC 28031
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 2/23/2016
Final Score @ Grade
32
General CommentsIntent to Suspend issued for record keeping, skimmer basket, depth markers, doors self-latching, self-closing. Note: PDSC form on file states pump is a EQ500. Actual pump is EQK500. Resubmit form with updated information for approval. Permit will not be issued until updated form is approved.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Alkalinity not recorded weekly. Record weekly. Intent to Suspend issued.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No One skimmer without basket. Replace basket. Intent to Suspend issued.Skimmer lid not flush on left skimmer at deep end of pool. Repair so flush. Protrusion is <1/2".
9 4 Pool maintenance: depth markings and no diving markers or signs visible and properly located No No No Wall depth markers replaced below water line. Room available to provide above water line. Move depth markers so visible. Intent to Suspend issued.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No One ladder handrail at shallow loose. Keep tight.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Back door into gym area not self-closing, self-latching. Repair to self-close, self-latch. Door in waiting area with latch removed. Repair to permanently lock or self-close, self-latch. Intent to Suspend issued.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck not sloped to drain. Standing water on deck. Repair to slope to drain.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Keep operational.Chlorinator could not be verified during inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Pump room floor with standing water. Keep dry.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash line direct plumbed. No air gap and could not trace. Will refer to Storm Water services.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Shower fixtures and shower heads with build-up in women's. Keep clean.