Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameYWCA OF THE CENTRAL CAROLINAS
Address3420 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 10/3/2022
Final Score @ Grade
12
General Comments30 Day Intent to Suspend (ITS) for automatic feeder shutting off with pump. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. Inspection with Jeff Nerret

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Automatic feeder not shutting off with pump. .2535 Automatic acid and chlorine feeder shall be automatically prevented from operating when the circulation pump is not in operation. *Permit item
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No No spare pump basket for pump. Pool built in '66, spare basket not available for pump to purchase. .2518(e) Provide a spare basket for pump.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chemicals stored in pump room. Pool built prior to 2004 (1966). .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2533
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash. Pool built 1966. .2513(b) Filter backwash shall be discharged through an air gap.