23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Automatic feeder not shutting off with pump.
.2535 Automatic acid and chlorine feeder shall be automatically prevented from operating when the circulation pump is not in operation.
*Permit item |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
No spare pump basket for pump. Pool built in '66, spare basket not available for pump to purchase.
.2518(e) Provide a spare basket for pump. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemicals stored in pump room. Pool built prior to 2004 (1966). .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.2533 |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash. Pool built 1966. .2513(b) Filter backwash shall be discharged through an air gap. |