Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameYWCA OF THE CENTRAL CAROLINAS
Address3420 PARK ROAD
 
City/State/ZIP
CHARLOTTE NC 28209
Premise Type53 - Year-Round Swimming Pool
CountyMecklenburg
Inspection Date 3/1/2021
Final Score @ Grade
14
General CommentsITS for records, flow meter and chlorinator leak. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS. "W" No signature due to COVID-19. Inspection with Jeff Nerret and Quentin Cockerham Report to Jeff Nerret ; quentin.cockerham@ymcacharlotte.org

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Records did not have daily main drain checks on all days. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity weekly. *30 Day Intent to Suspend (ITS) item
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Chlorinator had broken piece and leaking at time of inspection. .2535(6) Provide NSF approved automatic chlorinator installed per manufacturer instructions. *30 Day ITS item. Contact Marie Daley 704-507-6806 when in compliance to lift ITS.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No No spare pump basket for pump. Pool built in '66, spare basket not available for pump to purchase. .2518(e) Provide a spare basket for pump. Flow meter not operating at time of inspection. .2518(g) Keep flow meter operational. *30 Day ITS item. Contact Marie Daley at 704-507-6806 when in compliance to lift ITS.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Water on pump room floor. .2533(d) Pump room floor shall be kept dry and free of standing water. .2533(d) Pump room floor shall be sloped to drain. Chemicals stored in pump room. Water under pump and on pump room floor. Pool built prior to 2004 (1966). .2534(2) Pools constructed after April 1, 2004 shall provide a separate room for chemical storage meeting Rule.253 Hose bib in pump room observed without backflow prevention device. .2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room.