Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
.2535(6) Automatic chlorine and bromine feeder pumps shall be automatically prevented from operating when the circulation pump is not in operation. Observed control board not to demonstrate automatic shut off when flow stops. The control board must demonstrate automatic shut off while still powered but with no flow. Intent to Suspend issued. Deadline is 12/18/2025. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed pipe leaks in the pump room. Correct the leaks. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
.2526(i) Water in restrooms shall not exceed 110 F. Measured the water temperature to be 115F at the sink. |