Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameOLDE PROVIDENCE RACQUET CLUB - WADING
Address5952 SHARON VIEW ROAD
 
City/State/ZIP
CHARLOTTE NC 28226
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 5/16/2023
Final Score @ Grade
30
General CommentsNote: Sun shelf pool plaster does not meet >50% light reflectance. If re-plastered in future must meet >50% light reflectance. Inspection completed with Brandon Vaughn. Permit issued for no night swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Some debris under skimmer baskets. Keep clean so skimmers/filtration can operate correctly.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Pool barrier tie in to main building with horizontals at <45". Pool built pre-2010. Wading pool built post-2010. Maintain at 45" apart or greater.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Damage to deck at skimmer near bench. Repaired during the inspection. Deck drains >1/2" apart. Corrected during the inspection. Moved deck drains to close gap.
22 6 Premises: emergency telephone provided No No No Emergency phone not visible from pool deck. Signage added to pool rules sign located at entrance to wading pool stating located at front desk.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Original construction. If replaced, ensure flow meter is provided.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Observed lights not operable in the pump room and chemical storage room. Keep operational. Chlorine tabs stored in chemical storage room. Store in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap at backwash line to pit. Provide air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water in restrooms >115 F. Maintain at 110 F or below.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Hose bib not operable in men's restroom. Keep operational. Hose bib shall be provided so that every part of restroom can be reached with a 50 ft. hose.