8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Some debris under skimmer baskets. Keep clean so skimmers/filtration can operate correctly. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Pool barrier tie in to main building with horizontals at <45". Pool built pre-2010. Wading pool built post-2010. Maintain at 45" apart or greater. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Damage to deck at skimmer near bench. Repaired during the inspection.
Deck drains >1/2" apart. Corrected during the inspection. Moved deck drains to close gap. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone not visible from pool deck. Signage added to pool rules sign located at entrance to wading pool stating located at front desk. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No flow meter on chlorinator. Original construction. If replaced, ensure flow meter is provided. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Observed lights not operable in the pump room and chemical storage room. Keep operational.
Chlorine tabs stored in chemical storage room. Store in chemical storage room. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
No air gap at backwash line to pit. Provide air gap. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water in restrooms >115 F. Maintain at 110 F or below. |
|
33
|
2
|
Dressing and sanitary facilities: hose bibbs and floor drains provided |
No |
No
|
No |
Hose bib not operable in men's restroom. Keep operational. Hose bib shall be provided so that every part of restroom can be reached with a 50 ft. hose. |