| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed chlorine at 1.0 ppm with no NSF chlorinator. Pool installed chlorinator during inspection and raised chlorine to 2.0 ppm. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Wading pool pH was at 7.3 during inspection. Due to addition of chlorinator, pH dropped to below 6.8. Immediate Suspension issued. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Main drain checks not recorded regularly. Record daily. Cyanuric acid and alkalinity not recorded weekly. Record weekly. Intent to Suspend item. |
|
12
|
4
|
Pool maintenance: inlets and other fittings in place and in good repair |
No |
No
|
No |
Spray inserts missing on some features. Install to assure no openings greater than 1/2". Intent to Suspend item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Gates on to pool deck with 37" between horizontals. Pool built prior to 2010. Observed 3" under gates at entry. Pool built prior to 2010.
Observed foothold outside of gate entry. Wall located directly next to fence/gate at 32" in height. Eliminate foothold at gate. Intent to Suspend item.
Gates swing away from wading pool. Gates shall swing into wading pool. Intent to Suspend item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Some damage to deck around overflow grate. Repair where needed. |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
No chlorinator installed. Install NSF approved chlorinator sized for wading pool. Lifeguard indicated tablets were being added through pump. Corrected during inspection. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Observed no flow meter installed. Install flow meter on return line. Intent to Suspend item. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Pump room left unlocked. Keep locked so public cannot access when not in use. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Water in restrooms >110 F. Maintain at 110 F or below. |