Inspection Date 8/18/2026
Final Score @ Grade
24
General CommentsPool issued for no night swimming. IFPR complete at time of visit. Play structure and slide removed. Posts remain in place and secure. New plaster and new drain covers. PDSC form approved. Permit Restriction: Flow meter must remain operable. Flow required at 44 gpm to 80 gpm to meet turnover and flow restriction of the number of returns. Brandon Vaughn present during the inspection. Variable speed pump installed. Gallon size of pool obtained while onsite, 5,285 gallons with turnover at 44 gpm. 3" md, skimmer and return lines. Pentair TR140C filter (2) Hayward SP1082 skimmers at 55 gpm with EQ lines disabled. (4) returns - limiter. Permit Restriction set on above.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine at 0.8 ppm. Corrected to 2.0 ppm during the inspection through feeder.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No log book. Pool has not opened since 2024. Provide log book to maintain record keeping - chlorine, pH and main drain checks daily and cyanuric acid/total alkalinity weekly. Operator made phone call while onsite to get log book for site.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Windows into restrooms not limited. Corrected during the inspection. Fence post at side entry gate not secure. When pushed upon, stays in place. Operator made phone call and will have repaired by end of day. Fence still secure. Gates with >3" underneath. Multiple parts of barrier with 3" or greater underneath. Maintain 2" or less. Pool built 9/1/2006. Repair gate to 2" or less on both gates prior to 2027 operating permit. <45" between horizontals on wading pool fence and main fence. Maintain at 45" or greater between horizontals.
22 6 Premises: emergency telephone provided No No No Location of emergency phone not visible from pool deck. Location written on pool rules sign during the inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Vacuum line pipe and cleaning supplies in pump room, blocking access to equipment/pumps. Maintain 3 ft. clearance around equipment in all locations.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Hot water >113 F in restrooms. Maintain at 110 F or below.