2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine at 0.8 ppm. Corrected to 2.0 ppm during the inspection through feeder. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No log book. Pool has not opened since 2024. Provide log book to maintain record keeping - chlorine, pH and main drain checks daily and cyanuric acid/total alkalinity weekly. Operator made phone call while onsite to get log book for site. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Windows into restrooms not limited. Corrected during the inspection.
Fence post at side entry gate not secure. When pushed upon, stays in place. Operator made phone call and will have repaired by end of day. Fence still secure.
Gates with >3" underneath. Multiple parts of barrier with 3" or greater underneath. Maintain 2" or less. Pool built 9/1/2006. Repair gate to 2" or less on both gates prior to 2027 operating permit.
<45" between horizontals on wading pool fence and main fence. Maintain at 45" or greater between horizontals. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Location of emergency phone not visible from pool deck. Location written on pool rules sign during the inspection. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Vacuum line pipe and cleaning supplies in pump room, blocking access to equipment/pumps. Maintain 3 ft. clearance around equipment in all locations. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hot water >113 F in restrooms. Maintain at 110 F or below. |