2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine so high it bleached out reagents. Maintain safe chlorine levels. Operator partially drained and refilled, chlorine still above 10, but no longer bleached out reagents. pH changed to 7.2. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Main drain covers are recalled Waterway 640-470xV. Provide VGB complaint main drain covers. Operator installed 9MFxxx covers and submitted updated PDSC form.
Gap between wall and equalizer line cover. Operator filled gap with putty. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Emergency phone number does not match what 911 has. Corrected by operator. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Fan in pump room not working. Fix fan. |