Premises Information

Return to Inspections
NameVILLAGES AT ROSEDALE
Address9134 GREENHEATHER DR
 
City/State/ZIP
CHARLOTTE NC 28078
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 6/29/2023
Final Score @ Grade
18
General CommentsInspection conducted with CPO Mikey Cook. Note* Skimmer rated for 55 GPM. TR-60 filter rated for 63 GPM. Flow meter reading 69 GPM after a backwash. Permit denied. 5) 6) 22) There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No recent main drain checks, total alkalinity or cyanuric acid checks. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Flow meter reading 69 GPM after a backwash. PDSC form submitted said flow meter read 55 GPM. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
22 6 Premises: emergency telephone provided No No No Emergency phone not functioning. .2530(f) Emergency phone shall remain operable. - Pre-permit item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not functioning in pump room. .2533(e) Provide continuous forced ventilation or cross ventilation in pump room.