2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Chlorine puck in the skimmer. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Pre-permit item. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
PH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Currently writing in Chlorine and pH for both pools on the same sheet. No place for Total Alkalinity, Cyanuric Acid or Main Drain checks. Recommend two separate books. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Equalizer line cover plastered over at wall, not plugged in the skimmer per state guidance. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
Pool with one skimmer. Weir missing. .2518(k) Provide functional weir. - Pre-permit item. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Foothold at magnetic latch on gate. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item.
Horizontals on gates < 45” apart. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item.
Pool gate < 48” high where fence spike is missing. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. - Pre-permit item. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
Table beside wading pool. .2522 (c) Provide at least 4 ft clear walking space around wading pool at all times. - Pre-permit item. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not working. .2518(g) Keep flow meter operational. - Pre-permit item. |