Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGILEAD VILLAGE
Address13515 SWINTON DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 6/15/2023
Final Score @ Grade
38
General CommentsInspection conducted with CPO Mikey Cook. Restrooms connect main pool to the wading pool. Ensure doors remain self-closing and self-latching. Observed new motor on existing pump with 10/2023 manufacture date. No record that electrical permit and inspection have been obtained from Mecklenburg County Code Enforcement. - G.S. 130A-2(3) Ensure all electrical work is completed by a licensed electrician and electrical permit and passing inspection are obtained from Code Enforcement. - Pre-permit item. Pre-permit inspection did not pass 2, 3, 5, 6, 8, 16, 17, 24, electrical permit There is a $100 re-inspection fee that must be paid prior to scheduling a re-inspection by calling our office (980-314-1620) and paying with a credit card.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Chlorine puck in the skimmer. G.S. 130A-2(3) Chlorine added directly to swimming pool. Chlorination must occur through chlorinator. Eliminate direct hazard to public. - Pre-permit item.
3 6 Water quality: pool water pH No No No PH < 6.8. .2535(1) Maintain pH at 7.2 to 7.8. - Pre-permit item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Currently writing in Chlorine and pH for both pools on the same sheet. No place for Total Alkalinity, Cyanuric Acid or Main Drain checks. Recommend two separate books. .2535(11) Provide record keeping including daily records of disinfectant residual, pH, drain cover/grate inspections, pool water maintenance, and temperature, if applicable. Provide weekly recordings for cyanuric acid and total alkalinity. - Pre-permit item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No Equalizer line cover plastered over at wall, not plugged in the skimmer per state guidance. .2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. - Pre-permit item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Pool with one skimmer. Weir missing. .2518(k) Provide functional weir. - Pre-permit item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Foothold at magnetic latch on gate. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item. Horizontals on gates < 45” apart. .2528(b) Horizontals shall not be located less than 45" in height. - Pre-permit item. Pool gate < 48” high where fence spike is missing. .2528(a) Pool gate shall be at least 48" in height measured from outside of barrier. - Pre-permit item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Table beside wading pool. .2522 (c) Provide at least 4 ft clear walking space around wading pool at all times. - Pre-permit item.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter not working. .2518(g) Keep flow meter operational. - Pre-permit item.