Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameGILEAD VILLAGE
Address13515 SWINTON DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 6/26/2017
Final Score @ Grade
22
General Comments7) Plaster wearing thin. Walls damaged in places. Recommend patching and replastering before next season. 22) Emergency phone coming apart. Recommend replacing emergency phone. Pools tied together via the fill line. Recommend running separate fill lines. Grounding wire does not appear to be properly tied together. Recommend having a licensed electrician bond the pool to the pump motor and have it inspected by Code Enforcement. Wading pool grounded to pool. Unable to tell if it is actually grounded to the wading pool. Recommend having that checked. Immediate suspension issued 3) Contact Will Harrison (704-507-6824) for reinspection when issues have been corrected.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No pH 7.0. Maintain between 7.2 and 7.8. - Immediate suspension item.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No cyanuric acid or total alkalinity checks. Check daily Cl, pH, and main drains. Check at least weekly total alkalinity and cyanuric acid. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir not functioning. Missing the styrofoam float. Provide functional weir. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Fence < 48" high in places. Gap > 4" through the fence. Provide fence at least 48" high w/ no gaps > 4". Gap > 4" under gate to pool. Maintain gate w/ no gaps > 4" under the gate and maintain gate at least 48" high. - Intent to suspend item.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Leak where manual fill line enters pool return line. Fix leak. Fan in pump room tied to light switch. Fan shall run continuously. Chemical storage room being used for general storage. Store only chemicals in chemical storage room.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Provide backflow preventor for hose bib in pump room.