NameMONTEITH PARK
Address15245 WATERFRONT DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 8/6/2026
Final Score @ Grade
32
General CommentsPermit issued for no night swimming. Permit Restriction: Flow meter on feature pump shall remain operable with flow no greater than 119 gpm to not exceed the main drain covers. Suction Hazard.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No Pool pH at 8.2. Corrected to 7.2 during the inspection.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Weir in skimmer stuck in direction that would not allow for water flow through. Corrected during the inspection. Weir freely operable.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Barrier <48" in height with horizontals less than 40" apart. Pool built pre-May 1, 2010. Barrier shall be at least 48" in height with >45" between horizontals.
18 4 Premises: lifeguards present or warning signs posted No No No Pool rules signage missing "Adults should not swim alone" and "Children should not use the swimming pool without adult supervision" in 1" lettering. Sign posted at gate attendant entrance for visible for both pool and wading pool. Facility provided signage does not meet wording or height requirements.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No No flow meter on chlorinator. Provide flow meter, if replaced, to meet NSF approval.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter for feature not operable. Corrected during inspection. Reading 105 gpm within permit restriction. Permit restriction - shall not exceed 119 gpm due to drain cover flow restriction.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan in chemical storage room turned off. Ventilation shall run continuously. Turned on during the inspection. Recommend making switch inoperable so cannot be turned off. Muriatic acid for pool stored in front of equipment for wading pool and not in chemical storage room. Moved during the inspection. Store chemicals in chemical storage room. Bag of bicarb stored on floor in chemical storage room. Keep dry chemicals stored up off the floor.
28 2 Dressing and sanitary facilities: bathhouse or rest rooms accessible; shower sign posted No No No Hot water handle at far sink furthest from door leaking in women's. Keep fixtures in good repair.
33 2 Dressing and sanitary facilities: hose bibbs and floor drains provided No No No Could not locate hose bib in restrooms. Provide hose bib within 50 ft. of restrooms with backflow prevention.