Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameMONTEITH PARK
Address15245 WATERFRONT DR
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 7/13/2017
Final Score @ Grade
26
General CommentsPool permit not posted. Post permit such that it is easily visible by pool bathers. Intent to suspend issued. 5) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No No chlorine in the wading pool. Maintain at least 2ppm free chlorine in the pool. - Corrected to 4 ppm.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Only one TA and CYA check for the last month. Check at least daily Cl, pH, main drains and at least weekly. - Intent to suspend item.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing weir. Install functional weir. - intent to suspend item. Skimmer basket full. Clean regularly.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate not self-closing and self-latching. Make gate self-closing and self-latching. - Intent to suspend item. Gates < 48" in height. Provide fencing that meets requirement in .2528, including at least 48" high, no gaps > 4", latch height of 54", and open away from the main pool (towards the wading pool). If new gate is installed gate must have at least 45" between horizontals. - Intent to suspend item. Fence 41 - 46" high. Maintain fence at least 48" high.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Chlorinator leaking. Fix leak. - Corrected by operator. Some chemicals stored in pump room. Store all chemicals in chemical storage room.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash.