Inspection Date 4/7/2026
Final Score @ Grade
20
General CommentsPermit Issued - No Night Swimming EHS recommends eventually removing/relocating slide so that main drains can be properly assessed and visualized.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
3 6 Water quality: pool water pH No No No .2535(1) Maintain pH at 7.2 to 7.8. pH at 6.8 at the beginning of inspection. Corrected to 7.2 during inspection.
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No .2537(14) Keep pool surface and pool floor free of debris. Observed main drains located underneath the slide blocked with leaves. Slide makes it incredibly difficult to verify condition of main drains. Leaves get lodged underneath slide and where main drains are located. It would be best practice to move the slide to verify and maintain condition of main drains in pool. Leaves were cleaned off during inspection and main drain covers were in good repair.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No .2521(b) Steps greater than 20 ft in width shall have one handrail every 10 ft.
18 4 Premises: lifeguards present or warning signs posted No No No .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. Faded Warning no life guard on duty posted on fence. Sign was replaced during inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No .2533(b) Provide sufficient lighting in pump room. .2534(6) Provide sufficient lighting in chemical storage room. Observed limited lighting in both the pump and chemical rooms.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No .2518(d) Piping and valves shall be labeled with color codes or labels. Observed faded piping labels. Relabel as needed.