Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed PDSC for the main drains are not matching up with what was submitted to the department. Permit Denial item. Resubmit PDCS forms to the department and a reinspection will be conducted. Contact the department to reschedule. |
|
7
|
4
|
Pool maintenance: pool walls and floor kept clean, free of debris and in good repair |
No |
No
|
No |
.2537(14) Keep pool surface and pool floor free of debris. Observed debris and leaves over the drains. CDI- CPO cleaned during the inspection. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Signage with legible letters providing dialing instructions, address of pool and pool telephone number shall be posted at the emergency phone. Observed two phone numbers listed at the emergency phone. Remove the incorrect number that is located on the telephone, The sign has the correct number.
.2530(f) Provide signage with location of emergency phone if not visible from all areas inside pool enclosure. Observed the phone is not visible from the pool. CDI - CPO provided the location of the phone on the POOL RULES sign. |