8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
.2518(k) Replace missing weirs.- Observed one of two missing weir. New weir replaced during the time of inspection. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
.2528(b) Horizontals shall not be located less than 45" in height.- Observed wooden panel leaning again the outside fence, making it possible as a tool to climb over the fence into pool area. Item was removed at the the time of inspection. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
.2530(f) Emergency phone shall remain operable.- Observed emergency phone is not working properly. Cannot call out to 911, or receive call back. Issue fixed at the time of inspection. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
.2518(g) Keep flow meter operational.- Observed flow meter stuck in the tube, not moving freely. Issue fixed at the time of inspection. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(d) Pump room floor shall be kept dry and free of standing water.- Observed wet flooring in the pump room due to leak pipe. Repair needed. Keep dry in the pump room. |