Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSTEELECROFT SWIM CLUB
Address15514 DEHAVILLAND DR.
 
City/State/ZIP
CHARLOTTE NC 28217
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 5/25/2021
Final Score @ Grade
14
General CommentsOnsite visit to pool with Jeff Gaeckle for construction final and operating permit inspection. Scope of Work - Remodel of existing wading pool. Profile changed to zero entry with sunshelf on opposite end. Main drains eliminated and feature system with bubblers added. Deck resurfaced with slip-resistant coating. No change to barrier. No changes to pump room or chemical storage room. Construction final passed. Permit issued for no night swimming. Verified (2) Hayward SP3207EE, 3/4 hp pumps. Pool built without main drains or equalizers. EQ lines plugged in skimmer. Note: No fresh air intake in chemical storage room with forced draw. Recommend installing fresh air intake per mechanical code.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Collar on one skimmer not secure. Secured during the inspection.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No >1/2" openings at deck drains. Corrected during the inspection.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor drain missing cover in pump room. Replace drain cover. Open hole in floor.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib in men's restroom and pump room without backflow prevention device. Provide backflow prevention devices on all hose bibs. Check valve in pump room listed as ASSE 1015. Required ASSE1013. Original construction. If ever changed, bring up to current code.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Flooring with chipping seal and does not appear slip-resistant in both restrooms. Keep flooring in good repair. Flooring shall be slip-resistant.