Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameNORTHSTONE COUNTRY CLUB-FEATURE
Address15801 NORTHSTONE DR.
 
City/State/ZIP
HUNTERSVILLE NC 28078
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 8/12/2024
Final Score @ Grade
22
General CommentsInspection conducted with CPO Jeremy Laurer. Some wall tiles missing. Prior to 2025 pool permit being issued, will need to replace missing wall tiles. Permit condition that pump must be set at maximum speed, 3450 RPM to meet turnover. Observed pump set at 3000 RPM. - Corrected. Pool with Vac-Alert SVRS. System must be tested at least monthly and recorded in log book. Recommend installing a valve on piping to make testing easier. CPO had to get in pool with rubber mat to test today. Verified in-field plan review items: 4 skimmers plugged per state guidelines. 7 returns Main drain, skimmer, return lines appear to be 4” piping. Pentair TR140C Filter. Permit issued. No Night Swimming.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No .2539(b) Pools with single main drain or drains <36" apart shall provide a safety vacuum release system (SVRS) or other methods of preventing bather entrapment. Per ANSI/ASME A112.19.17, these must be must be tested monthly per manufacture’s instructions and documented. - Corrected. Operator tested today.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No 3 sides of pool lined with lounge chairs. Only 3 feet of deck clearance. .2522 (c) Provide at least 4 ft clear walking space around wading pool at all times. - Corrected. Lounge chairs removed.
18 4 Premises: lifeguards present or warning signs posted No No No Warning - No Lifeguard on Duty signage heavily faded. .2530(c) Provide "Warning - No Lifeguard on Duty" in 4" lettering. - Corrected.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Eyeball fitting installed on vacuum line. .2518(f) Provide a vacuum cap or self-closing cap for pools built after May 1, 2010. - Corrected. Eyeball fitting removed and self-closing vacuum cap installed.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Some piping not labeled. .2518(d) Piping and valves shall be labeled with color codes or labels.
27 2 Equipment room: filter backwash discharged through an air gap No No No No air gap for backwash line. .2513(b) Filter backwash shall be discharged through an air gap.