3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH at 7.1, PO corrected pH to 7.3 |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(g) Provide a hose bib with backflow prevention device within 50 ft. of the equipment room. Observed hose bibs in pump room and clubhouse with no backflow prevention devices.
.2533(e) Provide continuous forced ventilation or cross ventilation in pump room. Chemical
storage room ceiling forced ventilation not functioning. Not enough ventilation for natural cross ventilation. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
.2513(b) Filter backwash shall be discharged through an air gap. Backwash pipe elbows below height of floor drain pit, no air gap.
GENERAL COMMENT: Permit issued |