Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameLEXINGTON WADING POOL
Address11030 TAVERNAY PARKWAY
 
City/State/ZIP
CHARLOTTE NC 28262
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 7/19/2016
Final Score @ Grade
36
General CommentsIntent to suspend issued. 5) 8) 16)

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No No records observed for wading pool, only the main pool. Check daily Cl, pH, main drains and at least weekly TA and CYA. - Intent to suspend item.
6 6 Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ No No No PDSC form does not match what is installed. Pump actually Pentair Challenger CHII-NI-1/2F.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Missing weir for only skimmer. Provide functional weir. - Intent to suspend item.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Gate not self-closing and self-latching. Provide self-closing and self-latching gate. - Intent to suspend item.
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Deck chairs too close to pool. Maintain at least 4 feet clear walkway around wading pool. Corrected.
22 6 Premises: emergency telephone provided No No No Emergency phone unhooked at time of inspection. Provide functional emergency phone. Corrected. Emergency phone around the corner out of sight. Provide signage alerting bathers to the location of the emergency phone.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter stuck. Repair or replace. Metal piping installed at pump. Recommend removing and replacing with schedule 40 PVC piping.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Fan not working in pump room or chemical storage room. Provide either cross or forced air ventilation for both rooms.
27 2 Equipment room: filter backwash discharged through an air gap No No No Provide air gap for backwash.