3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
pH 6.8. Maintain between 7.2 and 7.8. Corrected to 7.3. |
|
5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
No TA or CYA checks on site. Check daily Cl, pH, main drains and at least weekly TA and CYA. These records need to be readily available when an inspection is conducted. - Intent to suspend item. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Pool actually has Pentair Challenger CFII-NI-1 1/2 F pump. Provide updated and approved PDSC form. - Immediate suspension item. |
|
8
|
4
|
Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris |
No |
No
|
No |
All weirs missings. Install functional weir. - Intent to suspend item. |
|
18
|
4
|
Premises: lifeguards present or warning signs posted |
No |
No
|
No |
No lifeguard on duty or lifeguard stand in wading pool area. Provide either lifeguard or signage stating in at least 4 inch lettering "WARNING NO LIFEGUARD ON DUTY". Warning No Lifeguard on Duty sign posted by operator. |
|
22
|
6
|
Premises: emergency telephone provided |
No |
No
|
No |
Provide signage at emergency phone with address and phone number. Corrected by operator. |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter stuck. Repair or replace. |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Hole in wall in men's restroom. Maintain restrooms in good condition. |