5
|
4
|
Water quality: daily written records of water quality and test kit kept on site |
No |
No
|
No |
Record total alkalinity & cyanuric acid 1 x week, record main drain check 1 x day |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
Pump does not match VGB form information |
|
23
|
4
|
Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 |
No |
No
|
No |
Chlorine feeder doesn't appear to be working |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter not working |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Floor is wet, continuous forced or natural cross ventilation required, light burned out, walls in poor repair |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Backflow preventer required on hose bib with hose |