2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
.2531(a) Maintain chlorine in wading pools or children activity pools at least 2.0 ppm. Observed chlorine reading 0.6 ppm chlorine. CDI - Chlorine corrected to 3 ppm during visit. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
.2535(1) Maintain pH at 7.2 to 7.8. Observed pH reading 6.8. CDI - pH corrected to 7.4 during inspection. |
|
6
|
6
|
Submerged suction outlets meet ASME/ANSI A112.19.8-2007. Single drains protected. (.2537, .2539) GPM= ____Field verification complete=____ |
No |
No
|
No |
.2539(c) All pools, prior to permit issuance, shall provide documentation to the Department to verify suction outlet safety compliance. Observed 2 Aquastar A10RCFRxxx drain covers in place in wading pool. PDSC form shows 2 Paramount SDXRetro2’s. Permit denied. Submit PDSC form to the health department for approval. |
|
9
|
4
|
Pool maintenance: depth markings and no diving markers or signs visible and properly located |
No |
No
|
No |
.2523(c) Depth markers shall be 4 inches in height and of a contrasting color with the background, clearly visible. Observed depth markers at 2” of height. Correct depth markers to 4” lettering. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
.2533(d) Pump room floor shall be kept dry and free of standing water. Observed standing water in pump room. REPEAT |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
.2518(d) Piping and valves shall be labeled with color codes or labels. Observed labels on piping fading. REPEAT |