Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSWIMMING HOLE
Address630 LORIMER RD
 
City/State/ZIP
DAVIDSON NC 28036
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 7/18/2025
Final Score @ Grade
14
General CommentsOSV to pool with General Contractor, HOA and pool management group for return construction. Some items not complete at time of inspection. First visit made from 9:30 to 10:30. Return visit made from 11:45 - 12:35 to verify repairs. All items from previous inspection corrected except for repair to the floors in two restrooms and the floor in the pump room. No direct hazard to the public. Permit issued for no night swimming with condition that work on the floor shall be finished prior to Monday, July 28th. If work not complete, the permit will be suspended. Construction final passed with condition. Holds will be released on the project and the State permit will be posted online by end of business day. Permit Restriction: Flow meter shall remain operable. Flow required at 20 gpm to meet flow restriction of the number of returns. Hayward SP2670020VSP, 1.65 THP with (2) Aquastar 2017 A10RCFRxxx drain covers. Pool built without a skimmer.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Log books do not have section for daily main drain checks. Ensure daily record keeping for main drain checks. Log book should reflect section for main drain checks. Will verify on return visit.
11 2 Pool maintenance: diving equipment, ladders, steps and handrails properly placed, in good repair No No No No handrail at step entry into wading pool. Original construction. Recommend installing handrail. Ensure bonded.
23 4 Equipment room: chlorine or bromine automatic feeders that meet NSF Standard 50 No No No Flow meter for chlorinator leaking. Damaged while trying to repair. Replaced during the inspection. Will verify if leaking on return visit.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Floor in pump room wet due to leak at check valve. Contractor is working on slope so that floor slopes to the drain. Per plumbing code, if floor slopes to drain, no catch drain required. Floor wet around last filter closest to backwash pit. Ensure no leaks. Will verify on the return visit for final repair to the floor in the restrooms and the pump room floor. Floor in pump room not sloped to drain. Contractor currently working on grinding so that all areas slope to drain. Given until Monday, July 28th for repair. Received document from HOA and GC indicating work will be completed by required date. If work not completed, permit will be suspended.
32 2 Dressing and sanitary facilities: floors smooth, slip-resistant, kept clean No No No Two of five restrooms with flooring not sloped to drain. Contractor given until Monday, July 28th for final repair. If not corrected, permit will be suspended. Provided with letter from HOA and GC indicating work will be completed by required date. Floor shall slope to drain.