| CDI=Corrected During Inspection | |
R=Repeat Violation | |
VR=Verification Required | |
|
|
| Violation Item
| Demerits
| Violation Description
| CDI | R | VR |
|
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
>4" gap in fence, needs to be repaired |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
5' clear walkway around pool perimeter required |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Chemical room needs light and hole in wall fixed, floor is wet, Equipment room area needs light and floor is wet, gate needs to be locked |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
2" air gap required, backwash line to be plumbed to sanitary sewer |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Women's restroom needs soap & one shower not working |
|
24
|
4
|
Equipment room: approved pump, filter, and flow meter operating properly |
No |
No
|
No |
Flow meter is missing-one needs to be installed |
|