Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
Logo Main Menu
Mecklenburg County Health Dept
Public Health Inspections
Select your filters and click the Search button to search for data, or click Clear to clear all filters
 
  
 

Premises Information

Return to Inspections
NameSOUTHWOOD CONDOMINIUM
Address5813 SHARON ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 4/18/2017
Final Score @ Grade
20
General Comments#7 Observed minimal sediment/soil on wading pool floor. ** Vacuum. WADING POOL PERMIT CAN BE ISSUED. Post permit in visible location on pool deck.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No -- Skimmer missing weir. ** Weir installed during inspection. -- Some floating debris. ** Remove.
16 4 Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained No No No Decorative cut outs/(missing bricks) in wading pool barrier brick wall and ~2" wide decorative brick ledge on solid wading pool barrier brick wall provide step holds for access over barrier. Brick stair step that joins exterior side of wading pool solid brick wall barrier reduces overall outside approach to wading pool to <48". ** See .2528 Fences
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No -- Distance between wading pool edge and aluminum wading pool barrier fence line is ~2'. ** The width of the deck should be at least 4'. See .2522 (c) -- Pool furniture ~ 3' from wading pool edge. ** Maintain 4' of clear walking space.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No -- No light in chemical room. ** Provide. See .2534 (6) -- No natural cross draft ventilation or forced air ventilation in chemical or equipment room. ** Provide. See .2533 (e) & .2534 (3).
27 2 Equipment room: filter backwash discharged through an air gap No No No Filter backwash pipe angled down into sump. ** Backwash water should discharge through a complete air gap.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Toilets in restrooms dirty. ** Clean.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow protection on hose bib below mail boxes nor on hose bib in equipment room. ** Install vacuum breakers on hose bibs.