Premises Information

Return to Inspections
NameSHARON SOUTH
Address8437 KNIGHTS BRIDGE ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 6/8/2017
Final Score @ Grade
16
General CommentsEHS verified that information on current PDSC form to be correct at time of inspection. GC #17 Observed concrete chipped from pool deck between storage building & wall leading to men's restroom. ** Maintain deck in condition where there are no offsets > 1/2".

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Observed chlorine @ 1.0ppm. ** Maintain minimum chlorine level of at least 2.0ppm. Chlorine level raised to 3.0 while EHS on-site.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No -- Equipment room/ chemical room has double doors that have a vent in the bottom of each side; however, the equipment room/ chemical room does not have any natural cross draft ventilation or forced air ventilation. ** Provide proper ventilation. See .2533(e) & .2534(3) -- Equipment room/ (chemical room) floor wet under wading pool filtration system due water leaking from filter drain plug area (?) & from leak at pump (pipe seal?). ** Resolve. Keep equipment room/ chemical room dry.
26 2 Equipment room: valves and pipes identified by color codes or labels No No No Filtration system piping not identified (i.e. main drain line, skimmer line, etc.). ** Identify piping by labels or color codes.
27 2 Equipment room: filter backwash discharged through an air gap No No No Backwash water discharges into storm drain at far right corner of parking lot (lot located to right side of the clubhouse & pool). ** Backwash water shall be discharged through a suitable air gap. See .2513 (b)
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Women' shower has leak @ "elbow" plumbing joint before shower head. ** Resolve.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No Hose bib located in equipment room/ chemical room has no back flow protection. ** Install vacuum breaker on hose bib.