2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed chlorine @ 1.0ppm. ** Maintain minimum chlorine level of at least 2.0ppm. Chlorine level raised to 3.0 while EHS on-site. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
-- Equipment room/ chemical room has double doors that have a vent in the bottom of each side; however, the equipment room/ chemical room does not have any natural cross draft ventilation or forced air ventilation.
** Provide proper ventilation. See .2533(e) & .2534(3)
-- Equipment room/ (chemical room) floor wet under wading pool filtration system due water leaking from filter drain plug area (?) & from leak at pump (pipe seal?).
** Resolve. Keep equipment room/ chemical room dry. |
|
26
|
2
|
Equipment room: valves and pipes identified by color codes or labels |
No |
No
|
No |
Filtration system piping not identified (i.e. main drain line, skimmer line, etc.). ** Identify piping by labels or color codes. |
|
27
|
2
|
Equipment room: filter backwash discharged through an air gap |
No |
No
|
No |
Backwash water discharges into storm drain at far right corner of parking lot (lot located to right side of the clubhouse & pool).
** Backwash water shall be discharged through a suitable air gap. See .2513 (b) |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Women' shower has leak @ "elbow" plumbing joint before shower head. ** Resolve. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bib located in equipment room/ chemical room has no back flow protection. ** Install vacuum breaker on hose bib. |