Premises Information

Return to Inspections
NameSHARON SOUTH
Address8437 KNIGHTS BRIDGE ROAD
 
City/State/ZIP
CHARLOTTE NC 28210
Premise Type51 - Seasonal Wading Pool
CountyMecklenburg
Inspection Date 7/13/2015
Final Score @ Grade
32
General Comments#27 Backwash line in equipment room has no air gap & unable to determine if exterior discharge point w/air gap. Intent to Suspend Issued for #5, #8 (missing weir) & #17.

Violations

 
CDI=Corrected During Inspection  R=Repeat Violation  VR=Verification Required 
Violation Item Demerits Violation Description CDIRVRComments
2 6 Water quality: disinfectant residual provided by No No No Cl @ .6ppm. ** Maintain at least 2.0ppm. Cl raised to 6.0 ppm.
5 4 Water quality: daily written records of water quality and test kit kept on site No No No Record form does not include daily main drain checks. Weekly total alkalinity & cyanuric acid levels not being recorded. **Maintain complete records. (ITS)
7 4 Pool maintenance: pool walls and floor kept clean, free of debris and in good repair No No No Sediment/soil on wading pool floor. ** Remove sediment.
8 4 Pool maintenance: surface skimmers (with weirs, baskets and covers) or gutters clean, in good repair, and functioning properly, no floating debris No No No Skimmer interior ring chipped. **Replace if possible. Missing 1 (of 1) weir. ** Install. (ITS)
17 4 Premises: decks unobstructed, properly drained, free of trip hazards No No No Major deck damage @ skimmer skimmer and expansion joint has missing caulk. ** Correct. (ITS) Basket of pool toys at pool edge. 2 chairs 3' from wading pool edge. ** Maintain 4' of clear walking space.
24 4 Equipment room: approved pump, filter, and flow meter operating properly No No No Flow meter float stuck. ** Rectify.
25 2 Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure No No No Equipment/chemical room has no cross or forced air ventilation. Equipment /chemical room floor wet @ wading pool circulation system. Leak @ chlorine line connection. ** Correct.
29 2 Dressing and sanitary facilities: required fixtures provided, clean, and in good repair No No No Womens' shower inoperable/handle missing. ** Repair. Large gap around one of the shower drains. ** Fill//close gap.
30 2 Dressing and sanitary facilities: approved water source, no cross connections No No No No backflow prevention on hose bib (for hose). ** Install vacuum breaker.