2
|
6
|
Water quality: disinfectant residual provided by |
No |
No
|
No |
Observed chlorine @ .4ppm. ** Maintain chlorine at a minimum of at least 2ppm. Chlorine raised to 2.0ppm. |
|
3
|
6
|
Water quality: pool water pH |
No |
No
|
No |
Observed pH 6.8. ** Maintain pH 7.2 to 7.8. ** pH raised to 7.4 while EHS on-site. |
|
16
|
4
|
Premises: fence or barrier with self-closing, self-latching gates properly constructed and maintained |
No |
No
|
No |
Both wading pool gates have Magna latch release mechanisms @ ~51" above grade/ deck . ** Both Magna latches re-installed so that latch release mechanisms/ handles are 54" above grade. |
|
17
|
4
|
Premises: decks unobstructed, properly drained, free of trip hazards |
No |
No
|
No |
-- Wading pool deck has large old cement patch that is now broken into pieces creating > 1/2" offset.
** Area re-patched while EHS on-site.
-- Permanent base for large wading pool umbrella is ~2' from wading pool edge. ** There should be at least 4' of clear walking space around the entire pool. |
|
25
|
2
|
Equipment room: equipment and chemicals kept in a dry, well-ventilated enclosure |
No |
No
|
No |
Equipment/ chemical room has lots of high wall vents; however, there is no natural cross draft ventilation or forced air ventilation. See .2533(e) and .2534(3). |
|
29
|
2
|
Dressing and sanitary facilities: required fixtures provided, clean, and in good repair |
No |
No
|
No |
Observed hot water @ ~ 118F at lavatories & showers in restrooms. ** Maximum hot water temperature allowed is 110F. |
|
30
|
2
|
Dressing and sanitary facilities: approved water source, no cross connections |
No |
No
|
No |
Hose bibs in restrooms have no back flow protection.
** Install vacuum breaker on each hose bib. |